Key Benefits
M520 quatro 1m length truss
M520 is a high-capacity truss system which adapts to its users' needs. All events which require an outdoor stage, concert stage or podium will be well-served by the M520. Pin holes are located at a 90 degree angle to the ground for convenient access when truss is lying on a flat surface.
Dimensions
- Length (mm)
- 1000.0
- Width (mm)
- 529.0
- Height (mm)
- 529.0
- Main Chord Size (mm)
- 50x4
- Brace Size (mm)
- 25x3
Others
- Material
- Aluminium
- Weight per meter (kg)
- 12.86
- Connection system
- conical
- Truss Connector
- CCO
- Pin Type
- PO
- Standard Color
- Natural Aluminium
- Optional Color
- true
- Cell Clamps Compatibility
- 200, 400, 500, 600
| Span | mft | 6.0019.69 | 8.0026.25 | 10.0032.81 | 12.0039.37 | 14.0045.93 | 16.0052.49 |
| Centre Point Load (CPL) | kglbs | 2 367.005 218.34 | 1 956.004 312.24 | 1 652.003 642.03 | 1 402.303 091.54 | 1 184.902 612.25 | 1 019.602 247.83 |
| Deflection | mmin | 11.800.46 | 23.400.92 | 39.001.54 | 58.102.29 | 79.603.13 | 104.504.11 |
| Third Point Load (TPL) | kglbs | 1 451.003 198.90 | 1 257.002 771.21 | 1 098.002 420.67 | 968.002 134.07 | 862.001 900.38 | 764.701 685.87 |
| Deflection | mmin | 12.300.48 | 25.601.01 | 44.001.73 | 67.802.67 | 97.303.83 | 130.905.15 |
| Quarter Point Load (QPL) | kglbs | 1 083.002 387.60 | 967.002 131.87 | 851.501 877.23 | 701.201 545.88 | 592.501 306.24 | 509.801 123.92 |
| Deflection | mmin | 12.800.50 | 27.401.08 | 47.501.87 | 68.502.70 | 93.403.68 | 122.404.82 |
| Fifth Point Load (FPL) | kglbs | 866.001 909.20 | 797.001 757.08 | 709.601 564.40 | 584.301 288.16 | 493.701 088.42 | 424.80936.52 |
| Deflection | mmin | 13.100.52 | 28.701.13 | 50.301.98 | 72.502.85 | 98.803.89 | 129.205.09 |
| Uniformly Distributed Load (UDL) | kg/mlbs/ft | 817.20549.13 | 537.30361.05 | 340.60228.87 | 233.70157.04 | 169.30113.76 | 127.5085.68 |
| Deflection | mmin | 15.200.60 | 31.901.26 | 49.901.96 | 71.902.83 | 98.103.86 | 128.305.05 |
| Span | mft | 18.0059.06 | 20.0065.62 | 22.0072.18 | 24.0078.74 | 26.0085.30 | 28.0091.86 | 30.0098.43 |
| Centre Point Load (CPL) | kglbs | 889.001 959.91 | 782.701 725.56 | 694.001 530.01 | 618.601 363.78 | 553.401 220.04 | 496.101 093.71 | 445.30981.72 |
| Deflection | mmin | 133.205.24 | 165.706.52 | 202.107.96 | 242.709.56 | 287.6011.32 | 336.9013.26 | 391.0015.39 |
| Third Point Load (TPL) | kglbs | 666.801 470.04 | 587.001 294.11 | 520.501 147.50 | 463.901 022.72 | 415.00914.92 | 372.10820.34 | 334.00736.34 |
| Deflection | mmin | 166.006.54 | 205.208.08 | 248.809.80 | 296.7011.68 | 349.0013.74 | 405.8015.98 | 467.0018.39 |
| Quarter Point Load (QPL) | kglbs | 444.50979.95 | 391.30862.67 | 347.00765.00 | 309.30681.89 | 276.70610.02 | 248.10546.97 | 222.70490.97 |
| Deflection | mmin | 155.306.11 | 192.407.57 | 233.609.20 | 279.2010.99 | 329.1012.96 | 383.4015.09 | 442.3017.41 |
| Fifth Point Load (FPL) | kglbs | 370.40816.59 | 326.10718.93 | 289.20637.58 | 257.70568.13 | 230.60508.39 | 206.70455.69 | 185.60409.18 |
| Deflection | mmin | 163.906.45 | 202.707.98 | 245.809.68 | 293.3011.55 | 345.1013.59 | 401.4015.80 | 462.2018.20 |
| Uniformly Distributed Load (UDL) | kg/mlbs/ft | 98.8066.39 | 78.3052.62 | 63.1042.40 | 51.5034.61 | 42.6028.63 | 35.4023.79 | 29.7019.96 |
| Deflection | mmin | 162.706.41 | 201.307.93 | 244.209.61 | 291.3011.47 | 342.9013.50 | 398.9015.70 | 459.4018.09 |
All truss loading calculations are based on:
Truss supported or suspended at both ends • Static loading only • Loads applied at the node points • Self-weight of the truss is included in all listed load capacities • Spans consisting of different truss lengths • Interaction of bending moment and shear force at connector is considered • Structural analysis based on EN 1999 • All loading data should be multiplied by 0.85 to comply with BS 7905-2 and ANSI E1.2-2006 • For any other application, or in case of an assembled structure, contact MILOS or a structural engineer • Safety factors used: self-weight 1.35 / variable loads 1.5
Truss supported or suspended at both ends • Static loading only • Loads applied at the node points • Self-weight of the truss is included in all listed load capacities • Spans consisting of different truss lengths • Interaction of bending moment and shear force at connector is considered • Structural analysis based on EN 1999 • All loading data should be multiplied by 0.85 to comply with BS 7905-2 and ANSI E1.2-2006 • For any other application, or in case of an assembled structure, contact MILOS or a structural engineer • Safety factors used: self-weight 1.35 / variable loads 1.5