Steel program

Key Benefits

"A comprehensive ecosystem of trusses, towers, and roofs built for the most demanding tasks, powered by cutting-edge technology and ultra-high-strength steel materials."

"Solutions with a load capacity of over 120 tons and heights exceeding 20 meters are part of our standard portfolio."

 "We offer a wide range of educational courses, training programs, and hands-on workshops."

Adéla Papežová

Sales support

Adéla Papežová

 

  

Steel Truss

S-M530quatro
S-M780quatro
S-M1010rectangular
S-M1450rectangular
S-M2000fold
Versions available
Max. span up to35m40m45m50m60m
UDL up to314kg(with 20m span)495kg(with 20m span)673kg(with 20m span)925kg(with 30m span)1 094kg(with 30m span)
Center Point Load up to3 139kg(with 20m span)4 949kg(with 20m span)6 731kg(with 20m span)13 873kg(with 30m span)20 240kg(with 30m span)
Width (mm)530786585776768
Height (mm)5307861 0121 4532 003
Weight kg (ca. per meter)5269.2765125.1141.4
Main chord size (mm)60.3×460.3×460.3×4101.6×4101.6×4
Brace size (mm)33.7×2.648.3×3.248.3×3.260.3×460×60×4
Shortest segment length1 m1 m1 m1 m1 m
Longest segment length6 m6 m6 m6 m6 m
Custom length option
Connection systemforkforkforkforkfork
Static report
Certificate
Manual (EN 82079-1)
Standard colourblackblackblackblackblack
Optional colour
Identification label with serial number
Ceiling support
Attachment and hanging point positionas close as possible to node pointsas close as possible to node pointsas close as possible to node pointsas close as possible to node pointsas close as possible to node points
Type of series (B, U..)
Connector
Pin typePQPQPQPWPW
Materialsteel(main chord S700)steel(main chord S700)steel(main chord S700)steel(main chord S900)steel(main chord S900)
Can be used with clamp series
Middle beam
Integrated ladder

Steel Roofs

S-MR10-28×19-14m
S-MR10-32×19-14m
S-MR20-24×25
S-MR20-32×25-24m
Designpitchedpitchedpitchedpitched
Stage size28×19m32×19m24×25m32×25m
Clearance13.9m13.9m18.4m18.4m
Internal width28.5m32.5m24.7m32.7m
Internal depth15.8m15.8m20m20m
Main grid max. loading capacity50 000kg40 000kg100 000kg60 000kg
Total max. loading capacity68 000kg58 000kg128 000kg88 000kg
Materialsteelsteelsteelsteel
Basescaffoldscaffoldscaffoldscaffold
Static report
Training offer
Test setup
Manual
PA wing / frame option
PA wing / frame max. loading capacity18 000kg18 000kg28 000kg28 000kg
Side house option
Cantilever max. loading capacityN/AN/AN/AN/A
Main grid trussS-M1010S-M1010S-M1450S-M1450
TowersS-MT-PS-MT-PS-MT-QS-MT-Q
Number of towers6666
Ballast
Side wall keders
Wall material optionPVCPVCPVCPVC
Rooftop constructionkederkederkederkeder
Deadhang methodS-MT-P-10|LockingUnitS-MT-P-10|LockingUnitS-MT-Q-10|LockingUnitS-MT-Q-10|LockingUnit
Chain on standard head sectionchain 10×28chain 10×28chain 11×31chain 11×31
Transport solution
Setup time30h(20 skilled riggers)30h(20 skilled riggers)36h(24 skilled riggers)36h(24 skilled riggers)
Overall external width (m)51.15546.154.1
Overall external depth (m)20.320.325.625.6
Overall height (m)17.317.323.323.3
PA wing - internal width (m)8.58.58.78.7
PA wing - overall external width (m)999.59.5
Cantilever depth (m)3.53.54.54.5

Steel Towers

S-MT-P Steel Tower
S-MT-Q Steel Tower
S-MT-Q-PA
Overall height16m22.5m20m
Max Loading Capacityup to 47 000kgup to 70 000kg2 500kg
Base Footprint5×5m6.3×6.3m8×8m
Self-weight3 500kg6 100kg3 850kg
Tower materialsteelsteelsteel
Truss type in TowerS-QTPTS-QTQTS-QTQT
HelperN/AN/A
Base shapecrosscrosscross
Ballast on base
Extra ballast needed
Electric hoist needed
Training offer
Test setup
Static report
Manual
Deadhang solutionS-MT-P-10|LockingUnitS-MT-Q-10|LockingUnitN/A
Head section length (mm)N/AN/A2 000
Chain on standard head sectionchain 10×28 or 11×31chain 7×22 or 10×28N/A
Chain hoist fixing methodN/AN/Aroundsling
Guy Wire neededN/AN/A
Transport solution
Setup time4h (4 skilled riggers)4h (6 skilled riggers)4h (6 skilled riggers)

Steel truss is used for heavy-duty structures in large-scale events, stadium installations, industrial applications, and permanent constructions where exceptional load capacity and long spans are required. MILOS Steel Truss systems are manufactured from ultra-high-strength steel to maximize structural performance while reducing overall weight.

The main advantage of MILOS Steel Truss is its use of ultra-high-strength steel, which provides higher load capacity and reduced deflection compared to standard construction-grade steel.

Steel truss generally offers lower deflection than aluminium truss. The use of ultra-high-strength steel allows MILOS Steel Truss systems to achieve higher load capacities and longer spans in demanding applications.

Steel truss should be chosen when the project requires maximum strength, reduced deflection, or permanent installation where higher self-weight is not a limiting factor.

Yes. Steel truss is commonly used outdoors in stadiums, industrial structures, and permanent installations, provided it is properly protected against environmental conditions.

MILOS Steel Truss systems manufactured from ultra-high-strength steel are protected using primer and wet-paint coating systems designed to provide corrosion resistance and long-term durability.

Yes. Steel truss can be used for temporary events. Installation requires suitable machinery and handling equipment due to the weight and size of the components.

Steel truss is transported and stored in a similar way to aluminium truss systems. Due to its higher weight, suitable lifting and handling equipment and machinery is required.

In general, steel and aluminium truss systems are not directly combined unless specifically engineered adapters and structural approval are provided.

Yes. Structural calculations, load tables, and engineering documentation are available for MILOS Steel Truss systems.

Steel truss can achieve very high load capacities depending on geometry, span, and support conditions, making it suitable for extreme structural requirements.

Steel truss is assembled using bolted or pin connection systems designed for high-strength structural applications.

Yes. Regular inspections and maintenance are required to ensure long-term structural integrity, especially in outdoor environments. Please refer to the Steel Truss User Manual for further information.

Yes. Steel truss systems can be custom-engineered for specific project requirements, including unique spans, loads, and structural layouts.

All Steel Program

Subcategories

Steel Truss
Steel Truss

Steel Truss

Steel Towers & LED Gates
Steel Towers & LED Gates

Steel Towers & LED Gates

Steel roofs
Steel roofs

Steel roofs

In action



Manufacturing Excellence

Comprehensive and intensive training Comprehensive and intensive training
Educational manipulatives and tools Educational manipulatives and tools
Laser engraving Laser engraving
Construction assistance Construction assistance

What customers say

  • Bertrand Verhauwen

    Managing Director

    "MILOS combines innovative engineering, exceptional structural reliability, and true partnership. Their ability to deliver high-performance solutions quickly—while listening to customer feedback—makes them an invaluable partner for the most demanding festival projects."

  • Jakub Kuchta

    Technical Director

    "For more than a decade, MILOS has been our trusted partner, delivering outstanding quality, excellent product availability, and reliable solutions for everything from conferences and weddings to large-scale event structures."

  • Sergen Uluç

    Import/Export Specialist

    "For over 12 years, MILOS has consistently delivered outstanding quality, reliability, and engineering excellence—making it one of the most trusted brands we use for live events."

  • Ziad Lakis

    Brand Manager

    "MILOS is more than a supplier—it is a trusted engineering partner. From live events to complex permanent installations, their innovative solutions, technical expertise, and commitment to quality give us the confidence to deliver even the most demanding projects."

  • Marios Georgiou

    General Manager

    "For two decades, MILOS has been the only brand we trust. Exceptional quality, certified safety, and unwavering reliability give us complete confidence on every production—from international tours to world-class concerts."

Catalogue

Good to know

  • Versions available: rectangle, foldable
  • Max span up to 60 m
  • Center point of load up to 20 000 kg (30m span)
Steel Towers
S-M530quatro
S-M780quatro
S-M1010rectangular
S-M1450rectangular
S-M2000fold
Versions available
Max. span up to35m40m45m50m60m
UDL up to314kg(with 20m span)495kg(with 20m span)673kg(with 20m span)925kg(with 30m span)1 094kg(with 30m span)
Center Point Load up to3 139kg(with 20m span)4 949kg(with 20m span)6 731kg(with 20m span)13 873kg(with 30m span)20 240kg(with 30m span)
Width (mm)530786585776768
Height (mm)5307861 0121 4532 003
Weight kg (ca. per meter)5269.2765125.1141.4
Main chord size (mm)60.3×460.3×460.3×4101.6×4101.6×4
Brace size (mm)33.7×2.648.3×3.248.3×3.260.3×460×60×4
Shortest segment length1 m1 m1 m1 m1 m
Longest segment length6 m6 m6 m6 m6 m
Custom length option
Connection systemforkforkforkforkfork
Static report
Certificate
Manual (EN 82079-1)
Standard colourblackblackblackblackblack
Optional colour
Identification label with serial number
Ceiling support
Attachment and hanging point positionas close as possible to node pointsas close as possible to node pointsas close as possible to node pointsas close as possible to node pointsas close as possible to node points
Type of series (B, U..)
Connector
Pin typePQPQPQPWPW
Materialsteel(main chord S700)steel(main chord S700)steel(main chord S700)steel(main chord S900)steel(main chord S900)
Can be used with clamp series
Middle beam
Integrated ladder
All Steel truss

Subcategories

S-M530
S-M530

S-M530

S-M780
S-M780

S-M780

S-M1010
S-M1010

S-M1010

S-M1450
S-M1450

S-M1450

S-M2000
S-M2000

S-M2000

Good to know

  • Stage size up to 32 x 25 m
  • Total max. loading capacity up to 160 000 kg
  • Clearance up to 18.4 m
Steel Roofs
S-MR10-28×19-14m
S-MR10-32×19-14m
S-MR20-24×25
S-MR20-32×25-24m
Designpitchedpitchedpitchedpitched
Stage size28×19m32×19m24×25m32×25m
Clearance13.9m13.9m18.4m18.4m
Internal width28.5m32.5m24.7m32.7m
Internal depth15.8m15.8m20m20m
Main grid max. loading capacity50 000kg40 000kg100 000kg60 000kg
Total max. loading capacity68 000kg58 000kg128 000kg88 000kg
Materialsteelsteelsteelsteel
Basescaffoldscaffoldscaffoldscaffold
Static report
Training offer
Test setup
Manual
PA wing / frame option
PA wing / frame max. loading capacity18 000kg18 000kg28 000kg28 000kg
Side house option
Cantilever max. loading capacityN/AN/AN/AN/A
Main grid trussS-M1010S-M1010S-M1450S-M1450
TowersS-MT-PS-MT-PS-MT-QS-MT-Q
Number of towers6666
Ballast
Side wall keders
Wall material optionPVCPVCPVCPVC
Rooftop constructionkederkederkederkeder
Deadhang methodS-MT-P-10|LockingUnitS-MT-P-10|LockingUnitS-MT-Q-10|LockingUnitS-MT-Q-10|LockingUnit
Chain on standard head sectionchain 10×28chain 10×28chain 11×31chain 11×31
Transport solution
Setup time30h(20 skilled riggers)30h(20 skilled riggers)36h(24 skilled riggers)36h(24 skilled riggers)
Overall external width (m)51.15546.154.1
Overall external depth (m)20.320.325.625.6
Overall height (m)17.317.323.323.3
PA wing - internal width (m)8.58.58.78.7
PA wing - overall external width (m)999.59.5
Cantilever depth (m)3.53.54.54.5
All Steel Roofs

Explore steel roofs

S-MR10-28x19-14m

S-MR10-28x19-14m

Max loading capacity
125 500kg
Stage size
28x19m
S-MR10-32x19-14m

S-MR10-32x19-14m

Max loading capacity
113 000kg
Stage size
32x19m
S-MR20-24x25

S-MR20-24x25

Max loading capacity
159 350kg
Stage size
24x25m
S-MR20-32x25-24m

S-MR20-32x25-24m

Max loading capacity
137 750kg
Stage size
32x25m

Good to know

  • Total max. loading capacity up to 70 000 kg
  • Height up to 23 m
  • Constructed with MILOS Ultra-High-Strength steel trus
Large roofs
S-MT-P Steel Tower
S-MT-Q Steel Tower
S-MT-Q-PA
Overall height16m22.5m20m
Max Loading Capacityup to 47 000kgup to 70 000kg2 500kg
Base Footprint5×5m6.3×6.3m8×8m
Self-weight3 500kg6 100kg3 850kg
Tower materialsteelsteelsteel
Truss type in TowerS-QTPTS-QTQTS-QTQT
HelperN/AN/A
Base shapecrosscrosscross
Ballast on base
Extra ballast needed
Electric hoist needed
Training offer
Test setup
Static report
Manual
Deadhang solutionS-MT-P-10|LockingUnitS-MT-Q-10|LockingUnitN/A
Head section length (mm)N/AN/A2 000
Chain on standard head sectionchain 10×28 or 11×31chain 7×22 or 10×28N/A
Chain hoist fixing methodN/AN/Aroundsling
Guy Wire neededN/AN/A
Transport solution
Setup time4h (4 skilled riggers)4h (6 skilled riggers)4h (6 skilled riggers)
All Steel towers

Explore steel towers

S-MT-P Steel Tower

S-MT-P Steel Tower

Max. loading capacity
47 000kg
Overall height
16.0m
S-MT-Q Steel Tower

S-MT-Q Steel Tower

Max. loading capacity
70 000kg
Overall height
22.5m
S-MT-Q-PA

S-MT-Q-PA

Max. loading capacity
2 500kg
Overall height
20.0m